5 error indicators – NORAC UC5-BC-ECHO-VT User Manual

Page 17

Advertising
background image


13

Main Lift Switch:
While in Automatic Mode if the main lift up or down switch is momentarily pressed, the target
height is incrementally adjusted up or down. If the Double Tap Main option is enabled, this
feature is disabled.
If Headland Assist (Section 9.1) is enabled with the trigger as the main lift switch, then the
main lift switch will be used to control Headland Assist instead of the target height. The main
lift up switch will activate Headland Assist. By pressing main lift down, the system will return to
Automatic Mode.
Pressing and holding the main lift switch will always put the system into Manual Mode.

6.5 Error Indicators

If an error is detected in the system, the Error button will appear in the upper left corner of
the screen as shown in Figure 13. The boom with the error will go to its Manual state with
the ‘M’ or ‘A’ on the display flashing depending on whether the system is in Auto or Manual
mode.
Selecting the Error button allows all active system errors to be viewed (Figure 14). To
navigate between multiple errors, use the Next and Previous arrow buttons.

Applies to ECHO™ Only
The sensor underneath the boom on the display will change color depending on the type of

error. If the sensor turns red, it indicates that the sensor has lost communication with system.
If the sensor turns orange, it indicates that there is no data for that sensor.

Figure 13: Error Indicator

Figure 14: Sample Error Viewing Screen

Advertising