25

Select the appropriate serial number from the
selection box.
Continue this for each of the sensors, if
necessary.

After adding a roll sensor, Measured Roll will
appear. This should be zero when the boom is

level. The Zero button adjusts the measured roll
to zero.


For Active Roll Types with rods only:
The following screen is shown in the Sensor Setup Menu for Active Roll sprayers that use rods.

Ensure the sprayer chassis and boom is level.
Select Proxy button for the Boom Frame and
Intermediate Frame. Measure the distance from
the sensor to the corresponding rod and enter
that value. When the boom and chassis are
exactly level, press the “ZERO” to zero the roll

readings.

8.5.2. Valve Setup

Each valve must be setup and tuned correctly for optimum performance from the NORAC
UC5™ Spray Height Controller. When setting up the valves, the sprayer booms must have
room to move in their full range of motion. Make sure there are no obstructions, such as

power lines, that the booms may come into contact with.

Before setting up the valves manually, it is recommended you attempt the Automatic System
Setup. Starting the Automatic System Setup will load the default valve settings, which will make
the manual valve setup much simpler. At any time the Automatic System Setup can be
cancelled and the default settings are still stored.