NORAC UC5-BC-ECHO-VT User Manual
Page 31

27
Table 4: Output Channels
Module
Output Channel
Module
Output Channel
Left Up (prop. valve)
Valve Module
1
Valve Module
1
Left Down (prop. valve)
Valve Module
2
Valve Module
2
Right Up (prop. valve)
Valve Module
3
Valve Module
3
Right Down (prop. valve)
Valve Module
4
Valve Module
4
Main Down (prop. valve)
Valve Module
5
Valve Module
5
Main Up (prop. valve)
Valve Module
6
Valve Module
6
Roll CCW (prop. valve)
Valve Module
7
Input Module
5
Roll CW (prop. valve)
Valve Module
8
Input Module
4
Main Down
Input Module
1
Input Module
1
Main Up
Input Module
2
Input Module
2
Aux 1 (Bypass)
Input Module
3
Input Module
3
Aux 2
Input Module
4
Aux 3
Input Module
5
Aux 4
Input Module
6
Input Module
6
Default Output Channels
Alternative Output Channels
Function
In the case where the UC5™ Input Module is driving the roll (slant) function, use the
Alternative Output Channels section in Table 4 for the default output channels.