9 Options Menu

Several options are available to configure your UC5™ system to operate in different modes.
Navigate to the UC5™ Settings Menu (Section 8.1) and choose Options as shown in Figure
18
. The first screen of the Options menu is shown in Figure 19.

* The screens of virtual terminal may be different from the figures as shown in this section.

Figure 18: Selecting Options Menu

Figure 19: Options Menu

9.1 Remote Switches

When remote switches are enabled, the UC5™ can be put into Automatic or Manual Mode
using a remote switch connected to the Remote Auto and manual input lines. This feature can
still be used in conjunction with the Remote Auto line as the trigger in Headland Mode. The
Remote Auto and manual input lines are located on the UC5™ Input Module.

To activate Automatic Mode, momentarily apply system voltage (+12 VDC) to the Remote
Auto line. The voltage must always be applied after the display has been powered up. The
UC5™ will not go into Automatic Mode if voltage is applied to the Remote Auto input line
before the system is powered up.

To activate Manual Mode, momentarily apply system voltage to the Remote Manual line. The
Remote Manual function always has priority over the Automatic function. The pin location of
the input lines is different based on the sprayer configuration.

If the UC5™ Input Module is driving the roll (slant) output:
The Remote Auto line is located on pin 6 and pin 7 (either pin may be used) on the Thru 1
connector on the Input Module.

The Remote Manual line is located on pin 4 and pin 9 (either pin may be used) on the Thru 2
connector on the Input Module.

For all other applications:
The Remote Auto line is located on pin 6 and pin 7 (either pin may be used) on the Thru 1
connector on the Input Module.

The Remote Manual line is located on pin 5 and pin 8 (either pin may be used) on the Thru 1
connector on the Input Module.