WARNINGS

Check the supporting structure to be used to verify that it has

sufficient load carrying capacity to support the weight of the unit.

Suspend the heater only from the threaded nut retainers or with

a manufacturer provided kit. Do NOT suspend from the heater

cabinet.

5.0 Hanging the

Heater

5.2 Lifting and Suspending

When the heater is lifted for suspension, support the bottom of the heater with plywood

or other appropriately placed material. If the bottom is not supported, damage could

occur. Before hanging, verify that any screws used for holding shipping brackets were

re-installed in the cabinet.
Separated Combustion Models - Whether using the suspension points or a hanger

kit, when installing a Separated Combustion Model, any

unused suspension points

on the control side of the heater MUST be plugged. Plug these holes with the 1/2”

long cap screws and flat washers shipped in the bag with the heater. (See

FIGURE 6.)

5.1 Weights

Before suspending the heater, check the supporting structure to be used to verify that

it has sufficient load-carrying capacity to support the weight of the unit.

Standard Power Vent Model

Size 30 45 60 75 100

125

150 175, 200 225

250

300

350

400

lbs

54 59 67 72

96

101

172

187

203

215

269

294

306

kg

24 27 30 33

44

46

78

85

92

98

122

133

139

Separated Combustion Model

Size 30 45 60 75 100

125

150 175, 200 225

250

300

350

400

lbs

55 60 68 73

97

102

173

188

204

216

270

295

307

kg

25 27 31 33

44

46

78

85

93

98

122

134

138

FIGURE 6 - Separated

Combustion Models

- Plug the unused

suspension points on

the control side of the

heater with the three

1/2” long screws, P/N

203311, and the three

sealing washers, P/N

61658. Find the screws

and washers in the

literature bag shipped

inside the heater.

WARNING

Unit must be level for proper operation. Do not place or add

additional weight to the suspended heater. Hazard Levels, page 2.

5.2.1 Two-Point or Four-Point Suspension

The heater is equipped for either two-point or four-point suspension. A 3/8”-16 threaded

nut retainer is located at each suspension point.

NOTE: Four-point suspension is

required when installing an optional downturn nozzle. See Dimensions in Paragraph

4.2 and the illustration in

FIGURE 7A.