2 dimensions, 0 mounting, Figure 1 - dimensions (inches and mm) – Reznor RDF Unit Installation Manual User Manual

Page 5

Advertising
background image

I-RDF, PN148384R5, Page 5

4.2 Dimensions

FIGURE 1 - Dimensions (inches and mm)

Top

View

Control

Side

Front View

Rear View

A

(Full Length of Outside of Curb Cap)

D

(Inside of Curb Cap)

Z

Y

B

(Cabinet
Height)

2-5/8 (67)

Control

Compartment*

Blower

Compartment

Supply Wiring**

24V Wiring**

E

(Inside Width of Curb Cap)

X

U

W

T

V

C

(Cabinet Width)

1 (25)

Horizontal

Discharge

(T x U )

S

R

Outside Air

Opening

(R x S)

See Outside Air Hood or

Filter Cabinet Dimensions

on page 11.)

N

L

P

Q

M

G

K

J

F

H

Optional Return

Air

Opening (F x G)

Bottom

Discharge

(L x M)

3 (76)

Gas Supply

(Y and Z)

Dimensions (inches)

Model Sizes

A

B

C

D

E

F

G

H

J

K

L

M

1-20-3, 1-40-3,

1-50-3, 1-65-3

88

37-1/8

44-3/16 84-13/16 45-1/2 24-1/2 10-1/2 5-7/16 14-9/32 15-5/8 21-29/32

19-1/8

2-80-3, 2-120-3

88

48-11/16 68-1/4 84-13/16 69-1/2

52

16-1/4 5-5/16 10-15/16 15-1/2 27-9/32

27-7/32

3-180-3, 3-260-3 135-3/4

61-5/8

82-9/16 132-9/16 83-1/8 64-9/16 19-1/16 5-5/32 13-13/32 21-5/8

37

37-3/32

Model Sizes

N

P

Q

R

S

T

U

V

W

X

Y

Z

1-20-3, 1-40-3,

1-50-3, 1-65-3

7-11/16

14-5/8

12-5/8

31-1/8

31-1/8 21-3/4 18-3/4

7-3/4

5-1/4

13-1/8

8-9/16

42-7/32

2-80-3, 2-120-3

16-5/16 24-21/32 11-7/32 55-3/16

42-5/8 27-1/4 27-1/4 16-5/32 6-11/32 15-3/32

8-3/4

48-15/16

3-180-3, 3-260-3 14-9/16 31-9/16

7-7/16

67-1/8

55-9/16 36-3/4 36-3/4 14-7/16

4

20-7/8 8-11/16

56

Dimensions (mm)

Model Sizes

A

B

C

D

E

F

G

H

J

K

L

M

1-20-3, 1-40-3,

1-50-3, 1-65-3

2235

943

1122

2154

1156

622

267

138

363

397

556

486

2-80-3, 2-120-3

2235

1237

1734

2154

1765

1321

413

135

278

394

691

691

3-180-3, 3-260-3

3448

1565

2097

3367

2111

1640

484

131

341

549

940

942

Model Sizes

N

P

Q

R

S

T

U

V

W

X

Y

Z

1-20-3, 1-40-3,

1-50-3, 1-65-3

195

371

321

791

791

552

476

197

133

333

217

1072

2-80-3, 2-120-3

414

626

285

1402

1083

692

692

410

161

383

222

1243

3-180-3, 3-260-3

370

802

189

1705

1411

933

933

367

102

530

221

1422

* RDF-2 and RDF-3 sys-

tems have double hinged

doors as illustrated. Control

compartment on RDF-1 has

a single hinged door.
** Configuration is for

RDF-2 and RDF-3. The

supply connection on the

RDF-1 systems is above the

control wiring connection.

5.0 Mounting

Mounting the system is the responsibility of the installer. Verify that the supporting

structure has sufficient load-carrying capacity to support the weight.
Depending on the building and its use, determine whether or not additional measures

should be taken to reduce the effect of blower vibration and/or noise.
When selecting a location for an outdoor installation, position the unit so that the air

inlet will

NOT be facing into the prevailing wind. A minimum of 14" (356mm) clearance

is required from the bottom of the air inlet hood to the mounting surface.
Prior to installation, be sure that the method of support is in agreement with all local

building codes. For both indoor and outdoor installations, check for service platform

requirements. If an outdoor system is being installed with bottom discharge and/or

return air, a full perimeter roof curb is recommended.