SINGER 9100 User Manual

Page 42

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TO REMOVE AND REPLACE THE SHUTTLE

The shuttle can be removed for cleaning in the follow

ing manner.

1. Tilt machine back.

2. Turn hand wheel until needle bar is at its highest

point.

3. Remove bobbin case. Push shuttle race gate latches

A out toward left and right.

4. Remove shuttle race gate B and then shuttle body

C. Clean and oil shuttle area.

To replace the shuttle, fit it in the reverse order

Removing the shuttle

Remove two screws from top cover and lift cover from

machine.

Apply a drop of oil to each place indicated.

TO OIL THE MACHINE

Lubricating Top of Machine

Loosen screw on face plate and remove face plate.

Apply one drop of oil to all points indicated.

A

pl.ite Lubricating Behind Face Plate

screw

-40—