System Wiring

17

J6: General Purpose I/O

General purpose I/O is available on the Brick Motion Controller. All I/O is electrically isolated from the
drive. Inputs can be configured for sinking or sourcing applications. All Inputs are 12-24VDC. All
Outputs are 24V nominal operation, 0.5A maximum current. Outputs are robust against ESD and
overload.

J6 General Purpose I/O

(Female DB-37 Connector)

36

33

1

20

2

3

4

5

9

10

28

27

26

25

24

21

22

23

11

8

7

6

29

30

32

16

15

14

13

12

17

18

19

31

34

35

37

Pin #

Symbol

Function

Description

1 GPIN01 Input

Input

1

2 GPIN03 Input

Input

3

3 GPIN05 Input

Input

5

4 GPIN07 Input

Input

7

5 GPIN09 Input

Input

9

6 GPIN11 Input

Input

11

7 GPIN13 Input

Input

13

8 GPIN15 Input

Input

15

9

IN_COM 01-08

Input

Input 01 to 08 Common

10 N.C

Not

Connected

11

COM_EMT

Input

Common Emitter *

12

GP01-

Output

Sourcing Output 1 **

13

GP02-

Output

Sourcing Output 2 **

14

GP03-

Output

Sourcing Output 3 **

15

GP04-

Output

Sourcing Output 4 **

16

GP05-

Output

Sourcing Output 5 **

17

GP06-

Output

Sourcing Output 6 **

18

GP07-

Output

Sourcing Output 7 **

19

GP08-

Output

Sourcing Output 8 **

20 GPIN02 Input

Input

2

21 GPIN04 Input

Input

4

22 GPIN06 Input

Input

6

23 GPIN08 Input

Input

8

24 GPIN10 Input

Input

10

25 GPIN12 Input

Input

12

26 GPIN14 Input

Input

14

27 GPIN16 Input

Input

16

28

IN_COM_09-16

Input

Input 09 to 16 Common

29 COM_COL Input

Common Collector **

30

GP01+

Output

Sinking Output 1 *

31

GP02+

Output

Sinking Output 2 *

32 GP03+ Output

Sinking Output 3 *

33

GP04+

Output

Sinking Output 4 *

34

GP05+

Output

Sinking Output 5 *

35

GP06+

Output

Sinking Output 6 *

36

GP07+

Output

Sinking Output 7 *

37

GP08+

Output

Sinking Output 8 *

*For sinking outputs, connect the COM_EMT (pin11) line to the Analog Ground of the Power supply and the outputs to
the individual plus output lines, e.g. GPO1+
**For sourcing outputs, connect the COM_COL (pin29) line to 12-24V and the outputs to the individual minus output
lines, e.g., GPO1-
Do not mix topologies, i.e., all sinking or all sourcing outputs. If the common emitter is used, the common collector
should be unconnected. Conversely, if the common collector is used, the common emitter should be unconnected.