J7: Extra General Purpose I/O (Optional)

General purpose I/O is available on the Brick Motion Controller. All I/O is electrically isolated from the
drive. Inputs can be configured for sinking or sourcing applications. All Inputs are 12-24VDC. All
Outputs are 24V nominal operation, 0.5A maximum current. Outputs are robust against ESD and
overload.

J7 General Purpose I/O

(Female DB-37

Connector)

36

33

1

20

2

3

4

5

9

10

28

27

26

25

24

21

22

23

11

8

7

6

29

30

32

16

15

14

13

12

17

18

19

31

34

35

37

Pin #

Symbol

Function

Description

1 GPIN17 Input

Input

17

2 GPIN19 Input

Input

19

3 GPIN21 Input

Input

21

4 GPIN23 Input

Input

23

5 GPIN25 Input

Input

25

6 GPIN27 Input

Input

27

7 GPIN29 Input

Input

29

8 GPIN31 Input

Input

31

9

IN_COM 17-24

Input

Input 17 to 24 Common

10 N.C

Not

Connected

11

COM_EMT

Input

Common Emitter **

12

GPO9-

Output

Sourcing Output 9 **

13

GPO10-

Output

Sourcing Output 10 **

14

GPO11-

Output

Sourcing Output 11**

15

GPO12-

Output

Sourcing Output 12 **

16

GPO13-

Output

Sourcing Output 13 **

17

GPO14-

Output

Sourcing Output 14 **

18

GPO15-

Output

Sourcing Output 15 **

19

GPO16-

Output

Sourcing Output 16 **

20 GPIN18 Input

Input

18

21 GPIN20 Input

Input

20

22 GPIN22 Input

Input

22

23 GPIN24 Input

Input

24

24 GPIN26 Input

Input

26

25 GPIN28 Input

Input

28

26 GPIN30 Input

Input

30

27 GPIN32 Input

Input

32

28

IN_COM_25-32

Input

Input 25 to 32 Common

29 COM_COL Input

Common

Collector

*

30

GPO9+

Output

Sinking Output 9 *

31

GPO10+

Output

Sinking Output 10 *

32

GPO11+

Output

Sinking Output 11 *

33

GPO12+

Output

Sinking Output 12 *

34

GPO13+

Output

Sinking Output 13 *

35

GPO14+

Output

Sinking Output 14 *

36

GPO15+

Output

Sinking Output 15 *

37

GPO16+

Output

Sinking Output 16 *

*For sinking outputs, connect the COM_EMT (pin11) line to the Analog GND of the Power supply and the
outputs to the individual plus output lines, e.g. GPO9+
**For sourcing outputs, connect the COM_COL (pin29) line to 12-24V and the outputs to the individual
minus output lines, e.g., GPO9-
Do not mix topologies, i.e., all sinking or all sourcing outputs. If the common emitter is used, the common
collector should be unconnected. Conversely, if the common collector is used, the common emitter should be
unconnected.