Brick Motion Controller Hardware Reference Manual

18

System Wiring

Suggested M-Variable Addressing for the General Purpose I/O (J6)

Suggested M-var. #

Address

Notes

M0->

Y:$78800,0,1

Input 1 Data Line, J6 Pin 1

M1->

Y:$78800,1,1

Input 2 Data Line, J6 Pin 20

M2->

Y:$78800,2,1

Input 3 Data Line, J6 Pin 2

M3->

Y:$78800,3,1

Input 4 Data Line, J6 Pin 21

M4->

Y:$78800,4,1

Input 5 Data Line, J6 Pin 3

M5->

Y:$78800,5,1

Input 6 Data Line, J6 Pin 22

M6->

Y:$78800,6,1

Input 7 Data Line, J6 Pin 4

M7->

Y:$78800,7,1

Input 8 Data Line, J6 Pin 23

M8->

Y:$78801,0,1

Input 9 Data Line, J6 Pin 5

M9->

Y:$78801,1,1

Input 10 Data Line, J6 Pin 24

M10->

Y:$78801,2,1

Input 11 Data Line, J6 Pin 6

M11->

Y:$78801,3,1

Input 12 Data Line, J6 Pin 25

M12->

Y:$78801,4,1

Input 13 Data Line, J6 Pin 7

M13->

Y:$78801,5,1

Input 14 Data Line, J6 Pin 26

M14->

Y:$78801,6,1

Input 15 Data Line, J6 Pin 8

M15->

Y:$78801,7,1

Input 16 Data Line, J6 Pin 27

M32->

Y:$078802,0,1

Output 1 Data Line

12

30

M33->

Y:$078802,1,1

Output 2 Data Line

13

31

M34->

Y:$078802,2,1

Output 3 Data Line

14

32

M35->

Y:$078802,3,1

Output 4 Data Line

15

33

M36->

Y:$078802,4,1

Output 5 Data Line

16

34

M37->

Y:$078802,5,1

Output 6 Data Line

17

35

M38->

Y:$078802,6,1

Output 7 Data Line

18

36

M39->

Y:$078802,7,1

Output 8 Data Line

19

37

Do not mix topologies, i.e., all sinking or all sourcing outputs. If the common emitter is used, the
common collector should be unconnected. Conversely, if the common collector is used, the common