Operation Theory

45

When the trigger signal occurs before the first M scans of data are
converted, the amount of stored data could be fewer than the orig-
inally specified amount M_counter, as illustrated in Figure 4-6.
This situation can be avoided by setting M_enable. If M_enable is
set to 1, the trigger signal will be ignored until the first M scans of
data are converted, and it assures the user M scans of data under
pre-trigger mode, as illustrated in Figure 4-7. However, if
M_enable is set to 0, the trigger signal will be accepted any time,
as shown in Figure 4-6. Note that the total amount of stored data
will always be equal to the number in the M_counter because data
acquisition does not stop until a scan is completed.

Figure 4-6: Pre-trigger with M_enable=0 (Trigger occurs before M scans)

Acquisition_in_progress

Scan_start

AD_conversion

Scan_in_progress
(SSHOUT)(pin8 on CN2)

(M_Counter = M = 3, NumChan_Counter=4, PSC_Counter=0)

Acquired & stored data
(2 scans)

Operation start

Trigger