Operation Theory

81

intervals for both A/D and D/A operations. Note that once you
choose the TIMEBASE source, both A/D and D/A operations
will be affected because A/D and D/A operations share the
same TIMEBASE.

AFI[0]

Alternatively, you can also directly apply an external A/D con-
version signal to replace the internal ADCONV signal. This is
another way to achieve customized sampling frequencies. The
external ADCONV signal can only be inputted from the AFI[0].
As section 4.1 describes, the SI_counter triggers the genera-
tion of the A/D conversion signal, ADCONV, but when using
the AFI[0] to replace the internal ADCONV signal, the
SI_counter and the internally generated SCAN_START is not
effective. By controlling the ADCONV externally, you can sam-
ple the data according to external events. In this mode, the
Trigger signal and trigger mode settings are not available.

AFI[0] could also be used as SCAN_START signal for A/D
operations. Refer to section 4.1 and section 4.6 for detailed
descriptions of the SCAN_START signal. When using external
signal (AFI[0]) to replace the internal SCAN_START signal, the
pulse width of the AFI[0] must be greater than two time of the
period of Timebase. This feature is suitable for the DAQ-2200/
DAQe-2200/PXI-2200 Series, which can scan multiple chan-
nels data controlled by an external event. Note that the AFI[0]
is a multi-purpose input, and it can only be utilized for one func-
tion at any one time.

AFI[1]

Regarding the D/A operations, users could directly input the
external D/A update signal to replace the internal DAWR sig-
nal. This is another way to achieve customized D/A update
rates. The external DAWR signal can only be inputted from the
AFI[1]. Note that the AFI[1] is a multi-purpose input, and it can
only be utilized for one function at any one time. AFI[1] cur-
rently only has one function. ADLINK reserves it for future
development.