74

Operation Theory

Inside-Region Analog Trigger Condition

Figure 4-34 shows the inside-region analog trigger condition,
the trigger signal is generated when the input analog signal
level falls in the range between the High_Threshold and the
Low_Threshold voltages.

NOTE

The High_Threshold setting should be always higher

than the Low_Threshold voltage setting.

Figure 4-34: Inside-Region Analog Trigger Condition

High-Hysteresis Analog Trigger Condition

Figure 4-35 shows the high-hysteresis analog trigger condition,
the trigger signal is generated when the input analog signal
level is greater than the High_Threshold voltage, and the
Low_Threshold voltage determines the hysteresis duration.
Note the High_Threshold setting should be always higher then
the Low_Threshold voltage setting.