1 i/o port address – ADLINK ACL-8216 User Manual

Page 30

Advertising
background image

22 Registers Format

3.1 I/O Port Address

The ACL-8216 requires 16 consecutive addresses in the PC I/O address
space. The Table 4.1 shows the I/O address of each register with respect to
the base address. The function of each register also be shown.

I/O Address

Read

Write

Base + 0

Counter 0

Counter 0

Base + 1

Counter 1

Counter 1

Base + 2

Counter 2

Counter 2

Base + 3

Not Used

8254 Counter Control

Base + 4

A/D low byte

CH1 D/A low byte

Base + 5

A/D high byte

CH1 D/A high byte

Base + 6

DI low byte

CH2 D/A low byte

Base + 7

DI high byte

CH2 D/A high byte

Base + 8

Status Control

Clear Interrupt Request

Base + 9

Not Used

A/D Range Control

Base + 10

Not Used

Channel MUX

Base + 11

Not Used

Mode Control

Base + 12

Not Used

Software A/D trigger

Base + 13

Not Used

DO low byte

Base + 14

Not Used

DO high byte

Base + 15

Not Used

Not Used

Table 3.1 I/O Address