24 • Registers Format
Address : BASE +8
Attribute: read only
Data Format:
Bit
7
6
5
4
3
2
1
0
BASE+8
- - DRDY - - - - -
DRDY: Data Ready Signal.
1: A/D data is not ready
0: A/D conversion is completed.
It will be set to 1, when reading the low byte.