32 Registers Format

3.10 Internal Timer/Counter Register

Two counter of 8254 are used for periodically triggering the A/D conversion,
the left one is left free for user applications. The 8254 occupies 4 I/O address
locations in the ACL-8216 as shown blow. Users can refer to NEC's or Intel's
data sheet for a full description of the 8254 features, condensed information
is specified in Appendix B.

Address : BASE + 0 ~ BASE + 3
Attribute: read / write
Data Format:

Base + 0

Counter 0 Register ( R/W)

Base + 1

Counter 1 Register ( R/W)

Base + 2

Counter 2 Register ( R/W)

Base + 3

8254 CONTROL BYTE