ADLINK ACL-8216 User Manual

Page 66

Advertising
background image

58 C/C++ Library

5.19 _8216_AD_INT_Status

@ Description

Since the _8216_AD_INT_Start() function is executed in background,
you can issue the function _8216_AD_INT_Status to check the status
of interrupt operation.

@ Syntax

int _8216_AD_INT_Status( int *status , int *count )

@ Argument

status:

status of the INT data transfer

0: A/D INT is completed

1: A/D INT is not completed

count:

current conversion count number.

@ Return Code

ERR_NoError

ERR_BoardNoInit
ERR_AD_INTNotSet

@ Example

See demo program 'AD_Demo2.C'

5.20 _8216_AD_INT_Stop

@ Description

This function is used to stop the interrupt data transfer function. After
executing this function, the internal AD trigger is disable and the AD
timer is stopped. The function returns the number of the data which
has been transferred, no matter whether the AD interrupt data transfer
is stopped by this function or by the _8216_AD_INT_Start() itself.

@ Syntax

int _8216_AD_INT_Stop( int *count )

@ Argument

count:

the numbers of A/D data which has been

transferred.

@ Return Code

ERR_NoError
ERR_BoardNoInit
ERR_AD_INTNotSet

@ Example

See demo program 'AD_Demo2.C'