Figure 3-13, Basic digitizer acquisition timing, Figure 3-14 – ADLINK PCIe-9814 User Manual

Page 34: Varying sampling rates by adjusting

Advertising
background image

24

Operations

Figure 3-13: Basic Digitizer Acquisition Timing

To achieve sampling rates other than 80MS/s, a number for scan
interval counter needs only be specified. For example, if the scan
interval counter is set as 2, the equivalent sampling rate is 80MS/s
/ 2 = 40MS/s. If as 3, the equivalent sampling rate is 80MS/s / 3 =
26.66MS/s, and vice versa. The scan interval counter is 16 bits in
width, therefore the lowest sampling rate is 1.221kS/s (80MS/s /
65535).

Figure 3-14: Varying Sampling Rates by Adjusting Scan Interval Counter

TIMEBASE

DATA

D1

D253

D254

Acquisition
In Progress

Trigger

Acquisition initiates following this clock edge

D2

D3

D4

D255

D256

Analog

signal

Trigger mode = post-trigger, DataCnt = 256, ScanIntrv = 1

TIMEBASE

DATA

D1

Acquisition
In Progress

Trigger

Acquisition is initiated following this clock edge

D1

ScanIntrv = 1

D2

D3

D4

D5

D6

D7

D8

D9

D10

D2

D3

D4

D5

D6

D1

D2

D3

D4

ScanIntrv = 2

ScanIntrv = 3