Operations
25
PCIe-9814
Table 3-4: Counter Parameters and Description
3.7 Synchronizing Multiple Modules
The PCIe-9814 provides a dedicated connector as system syn-
chronization interface, enabling multiple module synchroniza-
tion. As shown, bi-directional SSI I/Os provides a flexible
connection between modules, allowing one SSI master PCIe-9814
to output SSI signals to other slave modules.For more accurate
synchronization between modules, external sampling clock or
external reference clock should be applied.
The table summarizes SSI functionalities.
Counter 
Name
Length
Valid Value
Description
ScanIntrv
16-bit
1-65535
Timebase divider to achieve 
equivalent sampling rate of the 
digitizer, where Sampling rate = 
Timebase / ScanIntrv
DataCnt
31-bit
1-2147483647
Specifies the amount of data to 
be acquired:
1 - 2147483648 for pre-trig or 
mid-trig mode operation
trigDelayTicks 16-bit
1 -65535
Indicates time between a trigger 
event and commencement of 
acquisition. The unit of a delay 
count is the period of the 
Timebase.
ReTrgCnt
31-bit
1-2147483647
Enables re-trigger to accept 
multiple triggers.
1 - 2147483647 for normal 
operation
See Section 3.4.5: Acquisition 
with Re-Triggering
NOTE:
NOTE:
Different signals cannot be routed onto the same trigger bus 