Ditch Witch JT1220 User Manual

Page 154

Advertising
background image

JT1220 Mach 1 Operator’s Manual

Systems and Equipment - 153

Interpret Diagnostic Codes

CMW

163

no continuity to pipe up switch

pipe box movement is blocked and
code is stored

non-
essential

164

no continuity to tracker control input

code is stored

non-
essential

166

no continuity to thrust rear stop switch

code is stored

non-
essential

171

no continuity to pipe grip rocker switch

code is stored

non-
essential

172

no continuity to pipe shuttle rocker
switch

code is stored

non-
essential

173

no continuity to pipe lift rocker switch

code is stored

non-
essential

174

no continuity to pipe box rocker switch

code is stored

non-
essential

175

no continuity to pipe lube rocker
switch

code is stored

non-
essential

184

no continuity to throttle rocker switch

code is stored

non-
essential

185

no continuity to set/resume rocker
switch

code is stored

non-
essential

191

no continuity to engine speed sensor

code is stored

non-
essential

215

no continuity to float position sensor

assisted makeup is blocked and code
is stored

non-
essential

221

system voltage is below 12.5V

code is stored

non-
essential

233

drill and drive inputs both on

drill and drive are blocked

essential

234

add pipe and remove pipe inputs both
on

add pipe and remove pipe are
blocked

non-
essential

235

front home and rear home inputs both
on

add pipe and remove pipe are
blocked

non-
essential

241

shuttles not responding correctly

add pipe or remove pipe is aborted
and code is stored

non-
essential

251

float sensor is reading out of range

assisted makeup is blocked and code
is stored

non-
essential

254

error reading setup table information

add pipe and remove pipe are
blocked

essential

Code

Condition

Result

Severity

Advertising