Thresholds – EXFO VDSL2 User Manual
Page 56
Auto Tests
48
AXS-200/635i
Configuring Inactive Pair Test
Thresholds
The Thresholds tab displays the 
threshold parameters for the Inactive 
Pair Test. They are part of the CQ 
profile and cannot be edited on this 
pane.
Each parameter is described below:
³
Max. AC Voltage T-R (V) is the 
maximum AC threshold voltage for 
the T-R leg of the circuit.
³
Max. AC Voltage to GND (V) is the maximum AC threshold voltage to 
ground for the circuit.
³
Max. DC Voltage T-R (V) is the maximum DC threshold voltage for the 
T-R leg of the circuit.
³
Max. DC Voltage to GND (V) is the maximum DC threshold voltage to 
ground for the circuit.
³
Min. Metallic Insulation (MOhm) is the minimum threshold 
resistance for the circuit.
³
Max. Opens Variance (%) is the percentage maximum capacitance 
balance.
³
Max. Noise Metallic (dBrnC) is the maximum level of voice frequency 
noise.