Copper, VDSL2, ADSL2+ and IP Triple-Play Test Set
79
4
POTS Auto Test
The purpose of the POTS Auto Test function is to detect the Loop Current 
and measure the voice frequency in a copper telephone loop. This test 
allows you to compare measured results against stored threshold values to 
provide pass or fail status results of the POTS circuit type.
To access POTS Auto Test:
1. From the Home pane use the up/down arrow keys to highlight Fault 
Isolation Tools and press
.
2. Highlight POTS Auto Test and press
to start the test.
To view POTS Auto Test tabs:
From the POTS Auto Test pane use the F1, F2, or F3 key to view the various 
tabs.
Thresholds
The Thresholds tab allows you to set threshold values for the 
POTS auto test.
Each parameter is described below:
³
Min Loop Current (mA) is a value 
ranging from 10 to 100. Default 
is 23.
³
Max Loss (dB) is a value ranging 
from 0 to 50. Default is 8.
³
Max VF Power Influence is a value 
ranging from -90 to 10 dBm with a 
default of -10, if the ITU Standard is used. If ANSI Standard, the range is 
from 0 to 100 dBrn with a default value of 80.
³
Max Noise Metallic is a value ranging from -90 to 10 dBm with a 
default of -70, if the ITU Standard is used. If ANSI Standard, the range is 
from 0 to 100 dBrn with a default value of 20.
³
Min Long Balance (dB) is a value ranging from 0 to 100. Default is 60.