Sequence results, Statistics for frame loss parameters – EXFO AXS-200/850 Ethernet Test Set User Manual
Page 175
Advertising

Traffic Generation & Monitoring
Ethernet Test Set
165
Sequence Results
Sequence Results
Press ,
select
Traffic Generation & Monitoring, Results, and the
Sequence tab.
Statistics for Frame Loss Parameters
Frame Loss is declared when a missing sequence number is not received
within the next 20 ms. The frame loss parameters are applied to the main
stream only.
³
Seconds: Displays the total number of seconds in which one or
more Frame Loss event occurred.
³
Count: Displays the total
number of times the Frame
Loss event occurred.
³
Rate: Displays the rate of
frames that are lost during
transmission.
³
Threshold: Set the threshold
value for Count or Rate as per the
selected type of verdict. See
Frame Loss Pass/Fail Verdict on
page 134.
= PASS
= FAIL
Advertising