RFC 2544
Ethernet Test Set
85
Back-to-Back Results
³
Layer: Select the layer for determining the back-to-back results layer to
display. Choices are All, Ethernet and IP. The default setting is All.
³
All: Considers all layers to display the Back-to-Back Results and
represents the Ethernet line utilization.
³
Ethernet: Displays the Back-to-Back Results calculated at the
Ethernet layer.
³
IP: Displays the Back-to-Back Results calculated at the IP layer.
The back-to-back results displayed on the bottom half of the page are
displayed for the selected frame size distribution.
Note: When the Dual Test Set parameter is set to Local in Global Configuration
on page 58, the Back-to-Back subtest results are presented independently
for each direction: Local-to-Remote and Remote-to-Local.
Note: For DTS RFC 2544, the results for the
Local-to-Remote direction are
obtained between test iterations.
Note: The Pass/Fail verdict is displayed for
each frame size. To set the Pass/Fail
verdict, refer to the RFC 2544 Global
Configuration tab. See Pass/Fail
Verdict on page 60.
= PASS
= FAIL