Frame loss configuration – EXFO AXS-200/850 Ethernet Test Set User Manual
Page 81

RFC 2544
Ethernet Test Set
71
Frame Loss Configuration
Frame Loss Configuration
The objective of this test is to find the percentage of frames that are lost
due to lack of resources. Starting at the specified maximum rate
(Maximum Rate), the test is performed for a specific frame size and for the
specified duration (Test Time). The test is repeated by decreasing the
throughput by 10%, then the test is repeated again until there are two
successive trials in which no frames are lost. The test is performed for each
defined frame size.
Press ,
select
RFC 2544, Configuration, and the Frame Loss tab.
Note: This page is not available when the Dual Test Set parameter is set to
Remote in Global Configuration on page 58.
Note: Frame Loss must be enabled from Global Configuration on page 58.
³
Test Time (MM:SS): Select the
Test Time value. Possible values
are 1 second to 30 minutes. The
default setting is 1 second (00:01).
³
Maximum Rate: Select the Maximum Rate for the test, in terms of a
percentage of the line rate or in Mbps.