Installation – Glow-worm Clearly Heat Pumps Envirosorb2 User Manual

Page 30

Advertising
background image

0020117819_00 - 01/11 - Glow-worm

- 28 -

Envirosorb 8 flow/pressure curves

A

B

200

400

600

800

0

10

20

30

40

50

60

1

2

3

Key

1 Speed I

2 Speed II

3 Speed III

A Available pressure (kPa)

b flow in the circuit (l/h)

Envirosorb 12, Envirosorb 15 flow/pressure curves

A

B

200

400

600

800

0

10

20

30

40

50

60

70

80

1

2

3

Key

1 Speed I

2 Speed II

3 Speed III

A Available pressure (kPa)

b flow in the circuit (l/h)

15.2 Settings for the command unit

15.2.1

Appliance configuration parameters

i

If the parameters are changed, it is important to leave

the control box connected for at least 10 seconds so

that the change is properly saved.

• Press simultaneously on the button ( ) and (M) for 3

seconds. The parameter number is displayed and its value

blinks.

• Press the buttons (M) and ( ) to access the parameter "302".

The value of the parameter flashes.

Description of parameter 302

Setting

factory

setting

Min

Max

0 = Cooling only

1 = Heating + cooling

2 = Heating only

0

2

2

• Press the buttons (

) to modify the value.

• Press the button (M) or (OK) to confirm the parameter setting.

i

The other parameters 301, 303, 304, 305 and 306

must not be modified.

• Press the button (OK) to exit the menu and validate the

settings.

INSTAllATION