15.2.3

After-sales service parameters

This menu lets you make adjustments to the following functions

according to the appliances connected, and reset all these

parameters.

• Press simultaneously on button ( ) and ( ) for 3 seconds.

The parameter number is displayed and its value blinks.

• Press the button (M) to access the parameter. The value of the

parameter flashes.

• Press the buttons (

) to modify the value.

• Press the button (M) or (OK) to confirm the parameter setting.

• Press the buttons (

) to move to the next parameter.

• Perform the previous operations again for the other

parameters.

• Press the button (OK) to exit the menu and validate the

settings.

Code function

Description

Setting

factory

setting

Modifiable

parameter

Min

Max

100 Type of system

regulation

1 = Not used

2 = Regulation with system of management by contact

3 = Not used

4 = Not used

5 = Not used

6 = Not used

7 = Not used

1

7

2

Yes

101 Configuration of the

command unit

0 = Command unit used as configuration tool

1 = Not used

2 = Not used

0

2

0

Yes

102

Updates to the

command unit

software

This parameter displays the latest update to the software that is made on the

heat pump's command unit.

-

-

-

No

103

Version of the

command unit's

software

This parameter displays the version of the heat pump's command unit software

-

-

-

No

104 Test modes

By activating these various test modes, you can trigger special functions on the

appliance.

0 = No test

1 = Force the circulator

2 = Force output between terminals 5 and N (code 147)

3 = Force output between terminals 4 and N (code 106)

4 = Force output between terminals 11 and N (code 108)

5 = Force output between terminals 12 and N (code 156)

6 = Force the 3-way gate

7 = Not used

8 = Not used

0

9

0

Yes

105

Reset the counter

for the circulator

functioning time

This parameter resets, to zero, the functioning time counter for the heat pump's

circulator.

No

Yes

No

Yes

106

Configuration of

the output between

terminal channels 4

and N

Configuration of the booster heating

1 = Command booster heating

2 = Defrost output

1

2

1

Yes

107 Humidity rate

threshold

This parameter defines the humidity rate threshold from which the dehumidifier

is switched on.

20% 100%

50%

Yes

108

Configuration of

the output between

terminal channels 11

and N

Configuration of dehumidifier

1 = Alarm for unit and/or defrost

2 = Dehumidifier command

1

2

2

Yes

109 Threshold for protection

against frost

This parameter defines the temperature level of the installation's water from

which protection against frost is activated. This threshold corresponds to the set

temperature to which you should add 3°C.

0°C

6°C

0°C

Yes

110

Reset the counter

for the compressor's

functioning time

This parameter resets, to zero, the functioning time counter for the heat pump's

compressor.

No

Yes

No

Yes

111 Status of water flow

detector

This parameter lets you check the state of the water flow detector

1 = Sufficient water flow detected

0 = No water flow or insufficient flow

-

-

-

No