- 32 -

Code function

Description

Setting

factory

setting

Modifiable

parameter

Min

Max

126 Configurations

exterior sensor

Choose the type of exterior-temperature sensor:

1 = Remote sensor (connected onto terminal block 23 and 24)

2 = Sensor installed on the heat pump.

1

2

2

Yes

127 Exterior temperature This parameter displays the external temperature measured by the sensor

installed in the heat pump.

-

-

-

No

128

Temperature of

the cooling circuit

battery

This parameter displays the temperature of the heat pump's cooling circuit battery.

-

-

-

No

129 Compressor suction

temperature

This parameter displays the compressor's suction temperature.

-

-

-

No

130

Compressor

discharge

temperature

This parameter displays the compressor's discharge temperature.

-

-

-

No

131 Functioning state of

the heat pump

This parameter displays the functioning state of the heat pump:

1 = Stopped

2 = Cooling mode

3 = Heating mode

4 = Fault

5 = Defrost mode

-

-

-

No

132 Maximum frequency

of compressor

This parameter displays the maximum frequency of the compressor allowed by the

heat pump's command board.

-

-

-

No

133 Required compressor

frequency

This parameter displays the compressor frequency required by the heat pump's

command board.

-

-

-

No

134 Real compressor

frequency

This parameter displays the real frequency of the compressor variator.

-

-

-

No

135

Counter that times

the functioning of the

compressor

This parameter displays the number of hours during which the compressor has

functioned since first activation.

-

-

-

No

136 Capacity of the heat

pump

This parameter displays the capacity of the heat pump.

-

-

-

No

137

Return temperature

of the heat pump

circuit

This parameter displays the return temperature of the heat pump's circuit.

-

-

-

No

138

Flow temperature

of the heat pump's

circuit

This parameter displays the flow temperature of the heat pump's circuit.

-

-

-

No

139

Temperature of

the cooling fluid in

the plate to plate

exchanger

This parameter displays the temperature of the cooling fluid in the plate to plate

exchanger

-

-

-

No

140 State of functioning

of the system

This parameter displays the state of functioning of the system:

0 = Stopped

1 = Standby mode

2 = Cooling mode

3 = Heating mode

4 = Booster heating functioning

5 = Booster cooling functioning

4 = Nominal heating

5 = Nominal cooling

8 = Frost protection mode

9 = Defrost

10 = Protection against overheating

11 = Guard interval

12 = System fault

-

-

-

No

141 Fault codes

This parameter displays the fault codes for the heat pump.

-

-

-

No

142 Version of the heat

pump's software

This parameter displays the version of the heat pump's software.

-

-

-

No

143 Update to the heat

pump's software

This parameter displays the latest update made to the heat pump's software.

-

-

-

No

144

Counter that times

the functioning of the

circulator

This parameter displays the number of hours during which the circulator has

functioned since first activation.

-

-

-

No

145

Temperature setting

calculated for the

installation's water

This parameter displays the temperature setting for the installation's water

calculated by the command board according to climatic graphs.

-

-

-

No