Installation, 16 user information – Glow-worm Clearly Heat Pumps Envirosorb2 User Manual

Page 35

Advertising
background image

0020117819_00 - 01/11 - Glow-worm

- 33 -

Code function

Description

Setting

factory

setting

Modifiable

parameter

Min

Max

146

Configuration for

stopping the heat

pump if control by S1

contact input

1 = Immediate halt (as soon as contact S1 moves into the open position, the heat

pump stops).

2 = Gradual halt (as soon as contact S1 opens, the speed of the compressor

gradually reduces. This configuration is used to delay the shutdown of the

compressor after contact S1 switches to the open position and to limit the number

of compressor cycles per hour to 3.

1

2

2

Yes

147

Configuration of

the output between

terminal channels 5

and N

1 = Unit alarm

2 = Ambient temperature setting reached

1

2

1

Yes

148 limit exterior

temperature (T0)

This parameter defines the exterior temperature that is the functioning limit and where

the heat pump stops. In this configuration, only the booster heating functions. See the

chapter "Configuring the booster heating".

-20°C 65°C

-20°C

Yes

149

Choice of display in

the command unit's

temperature zone

1 = Ambient temperature

2 = Temperature of water leaving the installation

3 = Temperature of water returning to the installation

4 = Temperature of the cooling fluid in the plate to plate exchanger

5 = Compressor suction temperature

6 = Compressor discharge temperature

7 = Exterior temperature

1

7

1

Yes

150 Exterior temperature

bivalence point (T1)

This temperature defines the external temperature from which the power of the

heat pump alone is not sufficient to meet the needs of the installation. Below this

temperature, the booster heating and the heat pump can function together. See

the chapter "Configuring the booster heating".

30°C -20°C

0°C

Yes

151 Delays for switching

on booster heating

This parameter defines the period from which the booster heating is switched on

when: T0 < exterior T° < T1.

1

60

20

minutes

Yes

152 Differential stop/

start booster heating

This parameter defines the differential between the installation's water

temperature setting and the water temperature from which the booster heating

switches on when: T0 < exterior T° < T1.

1°C

20°C

5°C

Yes

153

Mode of activation

hot-water demand

contact S5

1 = Always active (demand for hot water is always met)

2 = Activated only in heating and cooling modes (demand for hot water is met only in

heating or cooling mode)

1

2

1

Yes

154 Booster heating

functioning

This parameter defines the functioning of the booster heating when: exterior T° < T0.

0 = Continuous functioning

1 = ON/OFF functioning depends on the ambient temperature.

In case of a thermostat fault, switch to mode 3.

2 = ON/OFF functioning depends on the installation's water temperature.

1

2

1

Yes

155 Functioning of main

circulator

This parameter defines the functioning mode for the main circulator for an external

temperature < T0 (code 148)

0 = Stopped

1 = ON/OFF cycle identical to the booster heating

2 = Continuous operation

0

2

1

Yes

156

Configuration of

the output between

terminals 12 and N

Configuration of the output (connection between terminal channels 12 and N)

0 = Not used

1 = ON/OFF cycle identical to the main pump The water pump works continuously

in case of demand for hot water.

2 = ON/OFF cycle identical to the main pump The pump is halted in case of demand

for hot water.

0

2

2

Yes

157 Functioning of the

additional circulator

This parameter defines the functioning mode for the additional circulator for an

external temperature < T0 (code 148)

0 = Stopped

1 = ON/OFF cycle identical to the booster heating

2 = Continuous operation

0

2

1

Yes

158

Differential on the

temperature setting

from the ambient air

This parameter defines the differential on the ambient temperature setting in the

case where the parameter 100 is configured to 4 (regulation with the command

unit used as the room thermostat).

+/-

0.2°C

+/-

1°C

+/- 0.3°C

No

- advise the user of the precautions necessary to prevent

damage to the system, appliance and the building;

- remind the user to service the appliance annually.

- The user shall not interfere with or adjust sealed components.

- All servicing must be carried out by a competent person

approved at the time by the Health and Safety Executive.

16 User information

At the end of the installation, the installer must:

- explain the operation of the appliance and its safety devices to

the user, if necessary provide a demonstration and answer any

questions;

- hand over to the user all the required documentation,

- fill in the documents where necessary;

INSTAllATION

Advertising