12

221966B

3.13 Domestic Hot Water Cylinder

SINGLE FEED INDIRECT CYLINDERS ARE NOT SUITABLE.

The domestic hot water cylinder must be if the indirect coil type.
It must be suitable for working at a gauge pressure of 0.35bar
above the safety valve setting.

3.14 Domestic Hot Water System - Unvented

Where a storage system will not have a vent to atmosphere the
installation must comply with Building Regulations and the
Local Water Company Byelaws, see also the current issue of
BS6700.

If fitting into an existing system, the local authority must also be
advised.

3.15 Filling a Sealed Water System

Provision for filling the system at low level must be made. Three
methods are shown in diagram 3.5. There must be no permanent
connection to the mains water supply, even through a non-
return valve.

3.16 Water Makeup

Provision must be made for replacing water lost from the
system. A make up vessel mounted above the highest point of
the system and connected through a non-return valve to the
system on the return side of either the hot water cylinder or
heating system, see diagram 3.4.

Alternatively provision for make up can be made by a filling loop.

3 LITRES (0.66 gals)
MAKE-UP BOTTLE
(if required)

NON-RETURN
VALVE

AUTO
AIR
VENT

FLOW

DRAIN
COCK

BOILER

SAFETY
VALVE

(Make-up
alternatives)

EXPANSION
VESSEL

PRESSURE
GAUGE

CIRCULATING
PUMP

FILLING POINT

AIR
RELEASE
POINT

HEATING

CIRCUIT

22mm (min)
BY-PASS WITH
LOCKSHIELD
VALVE

RETURN

Diagram 3.4

6252

(Make-up
alternatives)

METHOD 1

METHOD 2

METHOD 3

SUPPLY STOP
VALVE

SUPPLY
PIPE

HOSE
UNIONS

SERVICING
VALVE

TEMPORARY
HOSE

HEATING
SYSTEM

HEATING
SYSTEM

TEMPORARY
HOSE

HOSE
UNIONS

SERVICING
VALVE

SUPPLY
PIPE

SUPPLY STOP
VALVE

DOUBLE CHECK
VALVE ASSEMBLY

HEATING
SYSTEM

SERVICING
VALVE

SUPPLY
STOP VALVE

SUPPLY
PIPE

HOSE
UNIONS

DOUBLE CHECK
VALVE ASSEMBLY

OVERFLOW

CISTERN

COMBINED
CHECK VALVE
AND VACUUM
BREAKER

PRESSURE
REDUCING
VALVE

0051M

Diagram 3.5

3 Water Systems