10 servicing – Glow-worm Ultimate 100FF User Manual

Page 26

Advertising
background image

26

221966B

10.4 Electrode, Pilot Burner and Pilot Injector

Clean the pilot burner and electrode.

100FF Model Only. To remove the electrode release the spring
clip, see diagram 10.7.

120FF Model Only. To remove the electrode remove the
securing screw, see diagram 10.7.

When removing and replacing the pilot injector from the pilot
burner take care not to damage the electrode, see diagram 8.6,
clean the injector by blowing through it.

Check that the spark gap is as shown in diagram 8.3.

10.5 Operational Checks

After completing a service and before fitting the case, check
condition of the case seal and renew if necessary.

Examine the flue hood and terminal to make sure they are clean
and clear of obstructions.

Light the boiler and carry out the functional checks as described
in Section 8.

Testing Flue Gases: If any doubt exists that the flue products
are not exhausting correctly, investigate by use of a gas
analyser (FGA).

Diagram 10.5

Diagram 10.6

PILOT
BURNER

SPRING
CLIP

ELECTRODE

PILOT
INJECTOR

Diagram 10.7

PILOT
BURNER

PILOT
INJECTOR

SEMI STIFF
NYLON BRISTLES
CLEANING BRUSH

380mm MIN

40mm

20mm

50mm

CLEANING PLATE

MAIN BURNER
INJECTOR

ELECTRODE

SECURING
SCREW

ULTIMATE 120FF

ULTIMATE 100FF

4306

4299

4298

4299S

10 Servicing

Advertising