34

221966B

13.1 Part Identification

The key number in the diagram and the first column of the list
will help to identify the spare part.

13.2 Ordering

When ordering any spare part, please quote the part number
and the description from the list together with the model name
and serial number information from the data label. The data
label is positioned at the bottom right hand side of case.

If ordering from British Gas also quote the GC number of the
appliance from the data label and the GC number of the spare
part, from the list.

Diagram 12.6

RED

CLEAR

AIR PRESSURE
SWITCH TUBES

SECURING
SCREWS

AIR

PRESSURE

SWITCH

ELECTRICAL
CONNECTIONS

CONTROL
BOX

Diagram 12.7

9077

WATER PRESSURE
SWITCH

ELECTRICAL
CONNECTIONS

PURPLE

GREY

4304

12.14 Fan - diagram 5.3

Remove the electrical connections and disconnect the air
pressure tubes.

Remove the fan assembly securing screws.

Make sure that the earth connection is remade onto the new fan
assembly.

The polarity of the other connections is not important.

12 Replacement of Parts

12.15 Water Pressure Switch - Sealed Water
System Only

Release the water pressure and drain, refer to Section 3.

Disconnect the electrical connections at the microswitch, see
diagram 12.7.

Remove pressure switch.

On assembly, use new “O” ring, secure the water pressure
switch with locknut in the orientation shown as diagram 12.7.

Make up water loss and pressurise system, refer to
“Commissioning”.