12.9 Main Burner

Remove the main burner as Section 10.2.

12.10 Main Injector

Remove the main burner as Section 10.2.

Remove the main injector as Section 10.3.

12.11 Insulation - diagram 12.4

Combustion Chamber Front

Remove the retaining screw then the insulation.

Sides

Slide the insulation out.

12.12 Viewing Window - diagram 12.5

Remove the old self adhesive aluminium foil gasket and the old
mica window. Replace with a new mica window. Peel off the
backing paper and secure with new self adhesive aluminium foil
gasket, see diagram 12.5. Ensure no air bubbles are trapped
underneath the foil.

12.13 Air Pressure Switch - diagram 12.6

Release the control box as Section 7.1

Remove the pressure tubes and the electrical connections from
the PCB, release the screws and remove the switch.

When fitting the replacement make sure that the plastic tubes
and electrical connections are made as shown in diagram 11.5
and 12.6.

Diagram 12.3

SOLENOIDS

ELECTRICAL
PLUG

SECURING
SCREW

EXTENDED
SCREW
(8 off)

RESTRICTOR
(120FF Only)

PILOT PIPE
TUBING NUT

4302

12 Replacement of Parts

Diagram 12.4

SECURING SCREW

FRONT
INSULATION

SIDE INSULATION

4303

Diagram 12.5

SELF ADHESIVE
ALUMINIUM FOIL
GASKET

MICA WINDOW

PEEL OFF
BACKING
PAPER

OPENING
(INSIDE FACE
OF THE BOILER
FRONT COVER)

7907