1 general – Glow-worm Ultimate 100FF User Manual

Page 7

Advertising
background image

7

221966B

1.4 B.S.I. Certification

This boiler is certificated to the current issue of BS6332 Part 1,
invoking the current issue of BS5258 Part 1 for performance
and safety. It is, therefore, important that no alteration is made
to this boiler without permission, in writing, from Glow-worm.

Any alteration that is not approved by Glow-worm, could
invalidate the B.S.I. Certification of the boiler, warranty and
could also infringe the current issue of the Statutory
Requirements.

1.5 Gas Supply

The gas installation shall be in accordance with the relevant
standards.

In GB this is BS6891.

In IE this is the current edition of I.S.813 "Domestic Gas
Installations".

The supply from the governed meter must be of adequate size
to provide a steady inlet working pressure of 20mbar (8in wg) at
the boiler.

On completion test the gas installation using the pressure drop
method and suitable leak detection fluid, purge in accordance
with the current issue of BS6891.

1.6 Electrical Supply

WARNING: This boiler must be earthed.

All system components shall be of an approved type and shall
comply with and be connected in accordance with the current
issue of BS7671 and any applicable local regulations.

External wiring must be correctly earthed, polarised and in
accordance with the relevant standards.

In GB this is BS 6891.

In IE this is the current edition of I.S.813 "Domestic Gas
Installations".

Connection of the boiler and system controls to the mains
supply must be through a common isolator and must be fused
3A, maximum. This method of connection must be by a fused
double pole isolating switch with a minimum contact separation

26.44

90,210

32.38

110,485

23.45

80,000

29.31

100,000

33.43

114,066

39.6

135,150

29.3

100,000

35.17

120,000

3.5

125

4.2

148

29.24

99,760

26.38

90,000

9.2
3.7

14.4

5.8

11.6

4.7

2.8

100

3.5

123

3.1

111

205727

4.7mm

TABLE 2.

100FF

RANGE RATING

NOMINAL
HEAT
INPUT(NETT)

Min.

Max.

Med.

NOMINAL
HEAT
OUTPUT

APPROX.
GAS
RATE

BURNER INJECTOR MARKING:

kW

Btu/h

kW

Btu/h

m

3

/h

ft

3

/h

BURNER INJECTOR SIZE:

TABLE 2.

120FF

RANGE RATING

NOMINAL
HEAT
INPUT(NETT)

Min.

Max.

36.52

124,608

32.24

110,000

3.9

137

Medium.

NOMINAL
HEAT
OUTPUT

APPROX.
GAS
RATE

BURNER INJECTOR MARKING: 205726

kW

Btu/h

kW

Btu/h

m

3

/h

ft

3

/h

9.9
4.0

14.2

5.7

12.0

4.8

BURNER.
SETTING
PRESSURE

BURNER.
SETTING
PRESSURE

m bar

in. wg.

m bar

in. wg.

BURNER INJECTOR SIZE: 5.2mm

of 3mm on both poles. The switch should be readily accessible
and preferably adjacent to the appliance. It should supply the
appliance only and be easilyidentifiable as so doing.

Alternatively, an unswitched shuttered socket outlet and 3A
fused 3 pin plug both to the current issue of BS1363 may be
used, provided that they are not used in a room containing a
bath or shower.

Wiring to the boiler must be PVC insulated type to the current
issue of BS6500 Table 16.

1.7 Contents of Packaging

The boiler is delivered in one pack, refer to Section 4.1 for
contents.

Refer to Section 4.2 to check that the flue terminal assembly
supplied is suitable.

1.8 Water System

This boiler may be fitted to an open vented or sealed water
system.

1 General

DATA TABLE 1.

MODEL

TOTAL DRY
WEIGHT
(Including
Terminal)

LIFT WEIGHT

WATER
CONTENT

GAS
CONNECTION

ELECTRICITY
RATING

WATER
CONNECTION

ELECTRICITY
SUPPLY

DATA LABEL

100FF

Rc

1

/

2

in.

71W

97W

Internal fuse F1 & F2 (F1A)

2x28mm copper pipes from

top of case

230V~50Hz, fused 3A

Bottom right hand side of case

71.0 kg

(157 lb)

120FF

71.0 kg

(157 lb)

63.3 kg

(140 lb)

63.3 kg

(140 lb)

3.8 litres

(0.84 gal)

3.8 litres

(0.84 gal)

9072

*