0020112601_02 - 10/12 - Glow-worm

- 14 -

INSTALLATION

• Only use original seals supplied with the appliance.

• Check that there are no leaks. Repair if necessary.

1

2

3

4

5

6

7

8

6

7

Key

1 Heating return isolating valve + sealing washer ¾"

2 Cold water inlet isolating valve + sealing washer ¾"

3 Gas service isolating valve with pressure test point + sealing

washer ½"

4 Domestic hot water outlet isolating valve + sealing washer ¾"

5 Heating flow isolating valve + sealing washer ¾"

6 Connection Ø O.D. 22 mm

7 Connection Ø O.D. 15 mm

8 Gas connection Ø O.D. 15 mm

• Use only the original gas cock GER/1 DN15, CE-0085 CL

0082

• Use only the olive and flat seal washer supplied with the gas

cock.

• Remove the protective caps from the boiler connections.

• Flush out the domestic hot water and the heating systems.

i

Before turning on the cold mains supply to the boiler

turn off the cold water inlet to the boiler, lock the filling

loop in the closed position and close its filling taps.

8.2

Safety Discharge Valve

B

A

2

1

3

Key

1 Compression elbow

2 PRV pipe

3 Draining outlet

A PRV outlet - to outside

b Appliance drain tap

This must be extended, using not less than 15mm o.d. pipe,

to discharge, in a visible position, outside the building, facing

downwards, preferably over a drain.

To ease future servicing it is advisable to use a compression

type fitting to extend the safety discharge valve tube.

The pipe must have a continuous fall and be routed to a

position so that any discharge of water, possibly boiling,

or steam cannot create any danger to persons, damage to

property or external electrical components and wiring.