MAINTENANCE

• Check the expansion vessel's supply pressure (see «

Technical Data » chapter) by means of the pressure inlet

located on the expansion vessel. Adjust the pressure if

necessary.

• Following the installation of a new expansion vessel, fill and

purge the appliance or installation, if necessary.

18.7 Heating filter

B

B

C

A

A

A

E

D

1

5

4

3

2

1

2

Key

1 Plate-to-plate heat exchanger retaining arm

2 Plate-to-plate heat exchanger retaining screw

3 Gasket

4 Heating filter

5 Plate-to-plate heat exchanger

The heating filter improves the degassing of the heating circuit.

• Close the flow and return heating stop valves and drain the

boiler.

• Remove the retaining screw (2) and arm (1).

• Remove the plate-to-plate heat exchanger (5).

• Remove the gasket (3).

• Remove the heating filter (4).

• Clean and replace.

18.8 Condensate trap

a

Warning: condensate is mildly acidic. Use

protective gloves.

1

1

2

3

4

5

Key

1 The condensate trap

2 Discharge of condensates

3 Siphon

4 Condensate trap retaining clips

5 Hose

• Place a container under the condensate trap (1).

• Remove the siphon (3) from the condensate trap and clean.

• Disconnect the condensation discharge (2).

• Disconnect the heat exchanger hose (5).

• Remove the condensate trap (1) using the clips (4).

• Clean the hose, the trap and the siphon, remove any

accumulated dirt.

• Reassemble the components, taking care to position the

gaskets correctly.

• Start the siphon (3) and fill with water.