Introduction – Glow-worm Ultracom2 cxi User Manual

Page 5

Advertising
background image

0020112601_02 - 10/12 - Glow-worm

- 3 -

INTRODUCTION

INTRODUCTION

1 Instructions guidance

1.1

Product documentation

The instructions are an integral part of the appliance and must

be handed to the user on completion of the installation in order

to comply with the current regulation.

• Carefully read the manual, to understand all the information

to enable safe installation, use and servicing. No liability can

be accepted in the event of damage for not complying with

the guidance in this instruction manual.

These instructions consist of, Installation, Servicing, Fault Finding,

Replacement of Parts and Spares. The instructions are an integral

part of the appliance and must, to comply with the current issue of

the Gas Safety (Installation and Use) Regulations, be handed to

the user on completion of the installation.

1.2

Associated documents

- 1 Instructions for use

- 1 magnetic lighting instruction label

- 1 flue guide

- 1 extended guarantee leaflet

- 1 guarantee envelope pack

- 1 wall template

- 1 gas conversion label

1.3

Explanation of symbols

a

DANGER: Risk of injuries.

e

DANGER: Risk of electric shock.

b

ATTENTION: Risk of damage to the appliance or

to its surroundings.

i

IMPORTANT: Important information.

1.4

Guarantee registration

Thank you for installing a new Glow-worm appliance in your home.

Glow-worm appliances are manufactured to the very

highest standard so we are pleased to offer our customers a

Comprehensive Guarantee.

This product is guaranteed for 24 months from the date

of installation or 30 months from the date of manufacture,

whichever is the shorter, for parts and labour.

The second year of guarantee, from the beginning of the 13th

month onwards after installation or manufacture, is conditional

upon the boiler having been serviced by a

competent person

approved at the time by the Health and Safety Executive, in

accordance with the manufacturer’s recommendations. We

strongly recommend regular servicing of your gas appliance,

but where the condition is not met, any chargeable spare parts

or components issued within the applicable guarantee period

still benefit from a 12 month warranty from the date of issue by

the manufacturer.

We recommend you complete and return as soon as possible

your guarantee registration card. If your guarantee registration

card is missing you can obtain a copy or record your registration

by telephoning the Glow-worm Customer Service number

01773 828100.

2 Appliance description

2.1

Safety devices

2.1.1

Overheating safety

The appliance is designed to recognise the potential for an

overheat lockout and will shutdown before this happens.

2.1.2

Safety discharge valve

A safety discharge valve and discharge pipe are fitted to the

boiler. This valve must not be touched.

- The heating safety valve opens when the pressure in the

heating circuit exceeds 2.5 bars.

• Should there be any discharge from the pipe, isolate the

boiler electrical supply and call your installer or Glow-worm’s

own service organisation.

2.1.3

frost protection

The frost protection system operates the pump to start as soon

as the temperature in the heating circuit falls below 12°C. The

pump stops as soon as the temperature of the water contained

in the heating circuit reaches 15°C.

If the temperature in the heating system falls below 7°C, the

burner ignites until it reaches 35°C.

The frost-protection system is active when the appliance is

switched on.

The system alone cannot ensure that the installation is

protected against frost. An separate frost thermostat is

necessary to control the temperature of the system.

a

Your domestic water circuit (hot or cold) is not

protected by the boiler.

2.1.4

Condensate drain blockage

During freezing conditions this may be due to the forming of

ice in the condense drain external to the house. In this case, a

safety device shuts down the appliance.

Advertising