MAINTENANCE

Legend

1 Igniter unit retaining bracket

2 Igniter unit

3 Igniter unit retaining screw

4 Igniter unit electrical connector

5 Electrode / igniter unit connection cable

6 Earth cable

7 Spark electrode cap 8 Spark electrode retaining screw

9 Spark electrode gasket

10 Spark electrode

11 Combustion burner door assembly

12 Combustion burner door assembly - nut

13 Combustion burner door assembly - seal

14 burner gasket

15 burner

16 burner retaining screw

17 Heat exchanger retaining screw

18 Heat exchanger retaining bracket

19 burner gate retaining screw

20 Thermal fuse connection

21 Heat exchanger

22 Heat exchanger retaining bracket

23 Heat exchanger retaining screw

24 Heating return pipe

25 Heating return pipe retaining clip

26 Return heating temperature sensor

27 Heating flow pipe

28 flow heating temperature sensor

29 Heating flow pipe retaining clip

30 Gas valve retaining screw

31 Gas valve

32 Gas valve gasket

33 fan

34 fan electrical connection

35 fan/burner gasket

36 Gas pipe

37 Gas valve electrical connection

38 fan retaining screw

19.5.1

Spark electrode

• Disconnect the electrode cap (7) and the earthing cable (6).

• Remove the 2 spark electrode retaining screws (8).

• Carefully remove the electrode (10) from the combustion

chamber.

• Remove the gasket (9).

• Check that the distance between the 2 electrodes is between

3.5 and 4.5 mm.

• Install the electrode and a new gasket.

19.5.2

Igniter unit

• Remove the ignition lead (2).

• Remove electrical connections (4).

• Loosen the screws (3) located on the igniter unit (2).

• Remove the igniter unit (2).

19.5.3

Removing the combustion/burner door

assembly

b

Warning: The burner door seal (13) must be

replaced each time the combustion/burner door

assembly is removed.

• Disconnect the spark electrode cap (7) from the igniter unit.

• Disconnect the gas supply pipe (36) at the gas valve.

• Remove the electrical connectors from the gas valve (37)

and the fan (34).

• Remove the retaining screw of the silencer.

• Loosen the 4 nuts (12).

• Remove the combustion/burner door assembly from the heat

exchanger (11).

• The studs (19) must not be damaged. If damaged you will

need to replace the heat exchanger.

• The combustion/burner door assembly insulation should be

inspected and replaced if damaged.

19.5.4

burner

• Remove the 3 burner retaining screws (16).

• Remove the burner (15) and the gasket (14).

• Fit the new burner and the new gasket.

19.5.5

Heat exchanger

b

There will be water in the heat exchanger.

Carefully ease heat exchanger out.

• Drain the boiler heating and hot water circuits as described in

the appropriate chapter "Draining".

• Remove the flue connection.

• Undo the two screws located on the top of each side panel.

• Remove the thermal fuse connector (20).

• Remove the 2 heating pipe retaining clips (25) and (29).

• Release the heating pipes (24) and (27) from the heat

exchanger.

• Release the condensate trap pipe from the heat exchanger.

• Remove the combustion/burner door assembly (11)

refering to chapter "Removing the combustion/burner door

assembly".

• Unscrew the 4 retaining screws (17) and (23) and remove

the 2 retaining plates (18) and (22) from the heat exchanger.

• Pull the heat exchanger towards you to extract it from its 2

side rails.

Advertising