Installation – Glow-worm Ultracom2 cxi User Manual

Page 24

Advertising
background image

0020112601_02 - 10/12 - Glow-worm

- 22 -

INSTALLATION

11.3.1

230V permanent supply

a

All cables connected to the appliance should be

permanently fixed to the wall.

i

This appliance will not operate without a link or

system controls fitted.

24

V

1

2

3

4

Key

1 230V permanent supply

2 Main board terminal block

= Mains earth

N = Mains neutral

L = Mains live

3 fuse

4 Double pole connector

• Connect mains supply as described.

11.3.2

230V permanent supply + 230V system

controls

a

All cables connected to the appliance should be

permanently fixed to the wall.

i

This appliance will not operate without a link or

system controls fitted.

24

V

3

4

5

6

7

2

1

Key

1 230V permanent supply

2 System controls

3 frost stat

4 Main board terminal block

fP = frost stat 230V (switchable)

RT = Switch live (230V)

= Mains earth

N = Mains neutral

L = Mains live

5 Junction box

6 fuse

7 Double pole connector

• Connect the mains supply and system heating controls e.g.

room thermostat as described.

• When installing a 230v controller, the link fitted to the 24v

terminals (RT/24v) must be removed.

RT 24V

T° ext

BUS