Re-assembling the burner group

• Place the burner assembly on the heat exchanger (21).

• Progressively tighten the 4 nuts (12) in an alternate order.

• Reassemble the silencer.

• Connect the gas pipe (36) with a new gasket to the burner

group.

• Connect the spark electrode connector (5) to the igniter unit.

• Connect the connector to the gas valve (37) and the fan (34).

• Open the appliance’s gas input.

• Check the tightness of the gas connection.

19.5.7

Heating flow Thermistor

• Remove the electrical connections from the thermistor (28).

• Remove the retaining clip from the flow pipe (27).

i

When reconnecting, the polarity of the wiring to

thermistors is not important.

19.5.8

Heating Return Thermistor

• Remove the electrical connections from the thermistor (26).

• Remove the retaining clip from the return pipe (24).

i

When reconnecting, the polarity of the wiring to

thermistors is not important.

19.5.9

Gas valve

• Remove the burner door (11) refering to chapter "Dismantling

the burner door".

• Remove the two gas valve retaining screws (30).

• Remove the gas valve (31) and the gasket (32).

• Fit the new gas valve and the new gasket by repeating the

operations in reverse.

• After assembly test for gas tightness and purge in

accordance with the current issue of BS6891or in IE, the

current edition of I.S.813 “Domestic Gas Installations”.

• Check the combustion CO2.

19.5.10 fan

• Remove the burner door (11) refering to chapter "Dismantling

the burner door".

• Remove the gas valve (31) (see previous paragraph).

• Loosen the 3 screws (38) located on the burner door (11).

• Remove the fan (33) and the gasket (35).

• Fit the new gasket (35).

• Screw the new fan to the burner door (11).

• After assembly test for gas tightness and purge in

accordance with the current issue of BS6891or in IE, the

current edition of I.S.813 “Domestic Gas Installations”.

19.6 Condensate trap

a

Warning: condensate is mildly acidic. Wear

protective gloves.

1

1

2

3

4

5

Key

1 Condensate trap

2 Condensate outlet pipe

3 Condensate reservoir

4 Condensate reservoir retaining clips

5 Hose

• Place a container under the condensate trap (1).

• Remove the condensate (3) from the reservoir.

• Disconnect the condensation discharge (2).

• Disconnect the heat exchanger hose (5).

The condense trap will contain water, lift taking care not to spill

the water.

• Remove the condensate trap (1) using the clips (4).

• IMPORTANT: Partially fill the condensate trap with water

before replacing. Start the siphon (3) and fill with water.