INSTALLATION

• Do not use cable greater than 10 mm in diameter for the

electrical connections.

All system components must be of an approved type.

• Do not interrupt the mains supply with a time switch or

programmer.

The boiler is suitable for installation in bathroom zones 2 and 3.

11.1 Access to main board

2

1

4

3

Key

1 24 V access cover

2 Terminal blocks for 24 V connection

3 Terminal blocks for 230 V connection

4 230 V access cover

11.2 Main board

30mm

max

1

2

3

Key

1 Connector

2 Electrical wires

3 Insulation

When you connect the electrical wires to a connector on the

electronic board:

• Keep a distance of a maximum of 30 mm between connector

(1) and the start of the insulation (3).

• If using single core wires are used(2) ensure that the are

wrapped together in an insulating sheath.

• Fix the cables in the cable-clamp on the eBox.

11.3 Electrical wiring

Connection of the whole electrical system and any heating

system controls to the electrical supply must be through a

common isolator.

Isolation should preferably be by a double pole switched fused

spur box having a minimum contact separation of 3mm on each

pole. The fused spur box should be readily accessible and

preferably adjacent to the boiler. It should be identified as to its

use.

A fused three pin plug and shuttered socket outlet may be used

instead of a fused spur box provided that it is not used in a

room containing a fixed bath or shower.

24

V

1

Key

1 Power supply cable

• Connect the appliance's power cable to the 230 V single-

phase network + earth.

• Connect the appliance correctly to the live and neutral

connections.