INSTALLATION

2

C-BOX

1

2

VS

GND

USER INTERFACE

GND

V+ (10 - 30 Vdc)

Figure 7 - Power Supply Connections


The power supply must be between 10 and 30 Vdc only.

NOTE

Pin 1 is also electrically connected to pins 3 and 5, just as pin 2 is
electrically connected to pins 4 and 6. This is useful for external
trigger/inputs connections.


NOTE

The C-BOX 150 is protected against polarity reversal. A dedicated red
LED signals this condition until correct polarity is restored.



2.4.2 System

Wiring


The connection and wiring procedure for C-BOX 150 is described as follows:

1)

Open the C-BOX 150 as described in paragraph 2.2.

2)

Verify that the C-BOX 150 power switch is off (see Figure 6).

3)

Unscrew the compression connectors and pass all the system cables
through them into the C-BOX 150 housing.

4)

To connect the power and input/output signals:

Prepare the individual wires of the system cables by stripping the
insulation back approximately 1 cm.

9