Scanner Pinouts

Pin Name

1, 3, 5

VS

2, 4, 6

GND

7, 8

EARTH GROUND

*9, 13

RS485 CABLE SHIELD

20, 40

RESERVED

35 TX

AUX

37 RX

AUX

DS1100
DS2200

DS2100A
DS2400A

DS2100N
DS2400N

DS4600A

DS6X00 DX6400

DS8100A
DX8200A

21

OUT1+ OUT1+ OUT1+ OUT1+ OUT1+

22

IO REF

OUT REF

OUT1-

OUT1-

OUT1-

23

OUT2+ OUT2+ OUT2+ OUT2+ OUT2+

24

IO REF

OUT REF

OUT2-

OUT2-

OUT2-

25 NC NC

NC

RESERVED

OUT

3A

26 IN1- NC NC

RESERVED

OUT

3B

27

EXT TRIG+

EXT TRIG+

EXT TRIG A

EXT TRIG+

EXT TRIG/PS A

28

EXT TRIG-

EXT TRIG-

EXT TRIG B

EXT TRIG-

EXT TRIG/PS B

29

NC

NC

NC

IN1+

IN 2/ENC A

30

IO REF

NC

IN2-

IN1-

IN 2/ENC B

31 NC NC

NC

IN2+ IN

3A

32 NC NC

NC

IN2- IN

4A

33 RESERVED

RESERVED

RESERVED RESERVED

IN

3A

34 RESERVED

RESERVED

RESERVED RESERVED

IN

4A

36

NC

RTSA

ID-NET-

GND

IN 3B/IN 4B

38 NC

CTSA

ID-NET+

SGND

AUX

GND

39 SGND SGND GND SGND GND

DS2100A/N DS2400A/N DS4600A DS6X00 DX6400 DS8100A DX8200A

RS232 RS485FD

RS485HD

20mA

CL

(with INT-30 only)

*11, 15

TX232

TX485+

RTX485+

*12,

16 RTS232

TX485- RTX485-

17 RX232

RX485+

18 CTS232 RX485-
*10, 14, 19

SGND MAIN

SGND MAIN

SGND MAIN

See INT-30
instructions

DS1100 DS2200

RS485HD

*11, 15

RTX485+

*12, 16

RTX485-

17

RESERVED

18

RESERVED

*10, 14, 19

SGND MAIN

* The signals on pins 9, 10, 11 and 12 are repeated on pins 13, 14, 15 and 16 to facilitate network
connections (i.e. Multiplexer connections using the RS485 half-duplex Interface). In this way the network bus
can enter and exit the C-Box 150 from different spring clamps but be physically connected together.