Oxygen Monitors

Oxygen monitors allow the user to continuously monitor oxygen
levels inside the glove box. Monitors are normally placed inside the
main chamber to provide the best performance. Never operate a
transfer chamber vacuum evacuation on sensitive oxygen
monitors as damage can occur.

Part #

Descriptions

5244500

0-10,000 ppm Oxygen Monitor (with three ranges of 0-100 ppm, 100-
1,000 ppm, and 1,000-10,000 ppm) 100V/115V – 50/60 Hz

5244501

0-10,000 ppm Oxygen Monitor (with three ranges of 0-100 ppm, 100-
1,000 ppm, and 1,000-10,000 ppm) 230V – 50/60 Hz – International

5244400

0.1-100% Oxygen Monitor (1,000 ppm lowest) 100V/115V/230V –
50/60 Hz


12.

Moisture Monitors/Hygrometers

Moisture monitors or hygrometers allow the user to continuously monitor
moisture levels inside the glove box. Moisture monitors are normally
placed inside the main chamber to provide the best performance. Never
operate a transfer chamber vacuum evacuation on these sensitive
hygrometers as damage can occur.

Part #

Descriptions

5244900

1-1000 ppm Moisture Monitor/Hygrometer (Factory Set at 1-
1,000 ppm, with three settings of 1-10 ppm, 1-100 ppm, and 1-
1,000 ppm) 100V/115V – 50/60 Hz

5244901

1-1000 ppm Moisture Monitor/Hygrometer (Factory Set at 1-
1,000 ppm, with three settings of 1-10 ppm, 1-100 ppm, and 1-
1,000 ppm) 230V – 50/60 Hz – International

5244800

0-100% Hand Held Digital Hygrometer with Temperature
Display; measures relative humidity and temperature

5442200

Moisture Meter Probe and Calibration Stand -80 to 0°C dew
point range or 0 to 6000 ppm (Display is in dew point only)


13.

Exterior Monitor Plumbing Kits (Part #’s below)

The exterior monitor plumbing kits provide attachment plumbing to
oxygen or moisture monitors outside the glove box. Note: The control
and accuracy of the oxygen and moisture monitors will be reduced due to
the surrounding ambient air rather than inert gas inside the glove box.

Part #

Descriptions

Used With

5442400

Plumbing Kit for Oxygen Monitor (0 to 10,000 ppm)

5244500, 01

5442500

Plumbing Kit for Monitor/Hygrometer with pump (0 to 10,000 ppm)

5244900, 01

5442300

Plumbing Kit for Moisture Meter/Probe -80 to 0°C (or 0 to 6000 ppm)

5442200

14.

Automatic Pressure Controller (for use with Precise polyethylene

and manual control Protector Glove Boxes)
The Pressure Controller provides the operator the convenience of
automatically regulating pressure and vacuum within the glove box
main chamber and transfer chamber. The end user can also automate

Advertising