Powering the system, Connecting the battery, Installation of the gto transformer – Mighty Mule MM-SL2000B User Manual

Page 20: Step 1, Step 8, Step 3, Step 2, Step 4

Advertising
background image

8

SL-2000B Instruction Manual 04.26.12

POWERING THE SYSTEM

Step 1

Make sure the control box power switch is in the

OFF position.

ON-OFF

OFF

Step 8

Unscrew and remove the front cover of the control box

and slide battery into position with its terminals to the

left (see illustration). Make sure the battery fits snugly in control box.
Connect the black battery lead to the negative () terminal, and the red battery lead to the positive (+)

terminal. DO NOT allow battery leads to touch the control board! Touching the control board with battery

leads can short circuit the system!

RED

WIRE

to positive (+)

BLACK

WIRE

to negative (–)

Connecting the Battery

Choose the electrical outlet into which the transformer will be plugged. Measure the distance from the

electrical outlet to the control box, following the path where the low voltage wire will run (the maximum

distance can be no more than 1000 ft.).

Installation of the GTO Transformer

Step 3

Strip

3

/

16

” off the ends of the low voltage wire and attach ends to the

transformer terminals.

To prevent damage to transformer, make sure the exposed wire ends

do not touch each other!

NOTE: Wires coming from the ground to the control box should be run

through PVC conduit to protect them from damage.

Feed the low voltage wires upward through the strain relief on the bottom

of the control box (see Illustration J).

Illustration I

Step 2

Run the low voltage wire from the electrical outlet to the control box. Do not exceed 1000 ft..

NOTE: Pull approximately 1 ft. of low voltage wire into the control box to accommodate terminal

connections. To maintain adequate charging power, use appropriate gauge, stranded, direct burial wire

(see Accessory Catalog).

RED

BLK

ORG

BL

U

GRN

CLS EDG

OPN EDG

RED

GRN

ORG

BL

U

WHT

BLK

ORG

BL

U

GRN

CLS EDG

OPN EDG

LEARN

AUTO

CLOSE

INERTIA

BATT

+

OBSTRUCT

SENS.

RCVR

R G B

ALARM

SECOND OPERA

TOR

FIRST OPERA

TOR

POWER IN

18VAC SOLA

R

~ ~

– +

ACCES

SORY

PWR. SW

.

Operator Power Cable

PVC Conduit

Low Voltage Wire

from AC Transformer

Illustration J

Step 4

Strip

3

/

16

” off the ends of the low voltage wire and twist tightly.

These wire ends will be attached to the control board at the

18VAC terminals located on the POWER IN terminal block (see

Illustration L). Wire sheathing should not come in contact with

terminals, however, it should not be stripped so far that wires can

come in contact with one another (see Illustration K).