Control board settings, Dip switches – Mighty Mule MM-SL2000B User Manual

Page 22

Advertising
background image

10

SL-2000B Instruction Manual 04.26.12

CONTROL BOARD SETTINGS

1234

ON

OBSTRUCT

SENS.

PULL/PUSH

SEQ1

SNGL/DUAL

SEQ2

LEARN

DIP switches

MIN

MAX

RED

BLK

ORG

BL

U

GRN

CLS EDG

OPN EDG

RED

GRN

ORG

BL

U

WHT

BLK

ORG

BL

U

GRN

CLS EDG

OPN EDG

LEARN

AUTOCL

OSE

INERTIA

STATUS

PULL/PUSH

SNGL/DU

AL

SEQ1

SEQ2

MIN

MAX

MIN

MAX

OFF

60

120

BATT

+

OBSTRUCT

SENS.

RCVR

R B G

ALARM

SECOND OPERA

TOR

FIRST OPERA

TOR

POWER IN

18VAC SOLAR

~ ~ – +

ACCES

SORY

PWR. SW

.

DIP Switches

The four DIP switches on the control board match the operator with

the type of gate on which it is mounted. For example, gates may

open right to left or left to right. Prior to packaging, the SL-2000B

series control board was configured for a single slide gate that

opens right to left as viewed from inside of the property. If your

gate type matches this configuration, you DO NOT need to adjust

the DIP switches. Proceed to the Potentiometers section on the

next page.

NOTE: To change the DIP switch settings, you must turn the con-

trol box power switch OFF; move the switch; then turn the power

back ON. Use a small screwdriver to move the switches.

PULL/PUSH: Set to PULL for slide gates that open RIGHT to LEFT

[factory setting]; PUSH for slide gates that open LEFT to RIGHT.

SNGL/DUAL: Set to SNGL for a single gate leaf [factory setting];

DUAL for dual gate leaves.

Advertising