SL-2000B Instruction Manual 04.26.12

11

Potentiometers

The three (3) potentiometers on the control board operate like a volume control on a radio. They control the auto
close timer, inertia, and obstruction sensitivity of the operator. Use a small slotted screwdriver to turn the arrow
in the center of the potentiometer. Clockwise rotation increases the setting (MAX). Counterclockwise rotation
decreases the setting (MIN).

AUTO CLOSE (auto close timer): Determines how long the gate will remain
open before it automatically closes. The limits are OFF, or from 3 to 120
seconds. The factory setting is OFF.

INERTIA: Fine tunes obstruction sensitivity in the opening and closing

modes. INERTIA allows the operator to attempt to push an obstruction

clear of the gate path. When INERTIA is set to MIN the operator will

obstruct quickly (i.e, will attempt to push an obstruction briefly); when

set to MAX the operator will obstruct slowly (i.e., will push against an

object for a longer period). The factory setting is MIN.

OBSTRUCT SENS. (obstruction sensitivity): Determines the amount of

force exerted by the gate on an obstruction before the operator stops

and reverses. The gate will exert minimum force before obstructing

when set to MIN. When set to MAX, the operator will exert maximum

gate force before obstructing (i.e., the operator will require greater

resistance before stopping and reversing). The factory setting is MIN.

READ WARNING BELOW!

ALWAYS KEEP

SAFETY

AT THE TOP OF YOUR LIST WHEN ADJUSTING OR SERVICING YOUR

AUTOMATIC GATE OPERATOR!

1234

ON

AUTOCLOSE

INERTIA

OBSTRUCT

SENS.

RCVR

SEQ1

SEQ2

LEARN

R B G

PULL/PUSH

SNGL/DUAL

MIN

MAX

MIN

OFF

120

60

MAX

WARNING!

All three potentiometers were set to minimum at the factory. The OBSTRUCT SENS.

potentiometer MUST be adjusted above the factory setting for your SL-2000B operator to

function properly. If the potentiometer is left at MIN, your gate operator may “obstruct”

(i.e., stop and reverse) as soon as it is activated.

BE SURE TO PROPERLY RETEST THE GATE OPERATOR AFTER MAKING ANY ADJUSTMENTS;

FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.

Advertising