16

SL-2000B Instruction Manual 04.26.12

CONNECTING ACCESSORIES

The ACCESSORY terminal block is the connection point for accessories such as push buttons, safety loops,

intercoms, etc. The ACCESSORY terminal marked GRN (green) is the common ground for all accessories.

GRN is paired with the terminals shown below when connecting accessories to the control board.

IMPORTANT: Make sure to twist exposed wires tightly and insert them into the terminals without

loose strands. Tighten set screws against exposed end of wires.

Make sure the control box power switch is OFF before connecting accessories.

ON

FIRST OPERATOR

ALARM ACCESSORY

RCVR

SEQ1

SEQ2

LEARN

RED

BLK

ORG

BLU

GRN

CLS EDG

OPN EDG

BLU

ORG

WHT

GRN

R B G

Photo Beams (R4222)

Push Button Control (RB101)

Vehicle Sensor (FM139)

Refer to Vehicle Sensor

manual for additional

connections.

Edge Sensor

NOTE: There may be additional connection options for

applications that are not illustrated here.
Refer to accessory manuals for details.

7

4

5

4

4

Digital Keypad (F310)

6

4
7

1

2

ABC

3

DEF

4

GHI

5

JKL

6

MNO

7

PRS

8

TUV

9

WXY

0

4

3

2

1

5 6 7