CONNECTING SAFETY DEVICES

Make sure the control box power switch is OFF before connecting safety device wiring to the

terminal blocks.

Insert the safety device wires into the CLS EDG terminal (located on the FIRST OPERATOR terminal

block) for the gate closing mode. Connect the COMMON on the safey devices to the GRN

terminal. Connect the safety device wires for the gate opening mode to the OPN EDG terminal in

the same manner.

ON

SECOND OPERATOR

FIRST OPERATOR

POWER IN

ALARM ACCESSORY

RCVR

SEQ1

SEQ2

LEARN

18VAC SOLAR

~ ~ – +

RED

BLK

ORG

BLU

GRN

CLS EDG

OPN EDG

RED

BLK

BLU

ORG

ORG

BLU

WHT

GRN

GRN

CLS EDG

OPN EDG

R B G

Power Cable

from First Operator

Wire from Close Safety Edge

or Photoelectric Sensor

Wire from Open

Safety Edge or Photoelectric Sensor

Common

Common

The SL-2000B series operators are equipped with built-in obstruction detection. These operators are

designed to stop and reverse the gate for 2 seconds when it comes in contact with an obstruction.

Safety edges or photoelectric sensors MUST be installed on the gate.

Refer to the sensor manufacturer’s instructions for information about installing these devices on a

vehicular gate.

Power connections to
safety devices not shown.