FORM NO. L-21161-E-0108

10

Figure 

Table 1

Designation

Color

Function

I1

Green

"ON when +5 VDC is present

I2

Green

"ON" when +12 VDC is present

I3

Red

"ON" when increasing air pressure

I4

Red

"ON" when decreasing air pressure

I5

Yellow

"ON" when voltage is applied to boost Input

I6

Yellow

"ON" when voltage is applied to Machine State Input

I7

Yellow

"ON" when in manual control

Auxiliary

RS232 Port

Rotary

Switch

I6
I5

P3

P4

P5

Jumper

Indicator

12V

W4

10V
12V

W3

10V

R35
R38
R37

U4

DIG IN 2

W6

TX

DIG IN 1

W5

RX

I4
I3

I2

I7

I1

1

W2

2

U13

REV

W1

NORM

I OUT

W7

V OUT

Not Used

Optional

Pressure

Sensor

Connection

Red

black

White

J

uMPeR

anD

S

witCh

S

ettingS

: (R

efeR

to

f

iguRe

7.)

NORM, if controller action is backwards, then select REV

Position 1, enables RSD Communications for remote setup

10 V or 12 V, depends on maximum output voltage of sensor, use

10 V for Nexen’s DPS 30A or DPS 60A sensor, and 12V for mechanical potentiometer

10 V

Dig. In 1, if using this input for Start/Stopped Signal

Rx, if using this input for RS232 communication

Dig. In 2, if using this input for Splice Signal

Tx, if using this input for RS232 communication

V Out, for 0 – 10 VDC analog output

I Out, for 4 – 20 mA analog output

Refer to Table 2

Jumper W1

Jumper W2

Jumper W3

Jumper W4

Jumper W5

Jumper W6

Jumper W7

Rotary Switch